Shandong Bangju Industrial Co., Ltd. Self-Monitoring Plan
Release time:
2024-05-28
Shandong Bangju Industrial Co., Ltd. Self-Monitoring Plan
- Basic Information of the Enterprise
1.Legal Representative |
Wang Lei |
2. Former Name |
|
3. Organization Code |
91371203MA3CB5LU6L- |
4. Social Credit Code |
91371203MA3CB5LU6L |
5. Plan Review Address |
Shandong ProvinceProvince (Autonomous Region, Municipality)Jinan CityRegion (City, State, League) Steel City DistrictCounty (District, City, Banner) |
6. Detailed Address of the Enterprise |
Shandong ProvinceProvince (Autonomous Region, Municipality) Region (City, State, League) Steel City DistrictCounty (District, City, Banner) Township (Town) South New Town, Yihe Road South End, Steel City District, Jinan City, Shandong ProvinceStreet (Village), House Number |
7. Geographic Location of the Enterprise |
Central Longitude/Central Latitude 117,48,36.25/36,1,20.21 |
8. Contact Information |
Telephone Number:13326226121 Contact:Zhang Yuhui Mobile Number: Fax Number: Postal Code:271104 |
9. Registration Type |
|
10. Enterprise Scale |
Medium Type II |
11. Enterprise Category |
Industrial Enterprise |
12. Industry Category |
Industry Name:Manufacturing of Other General Parts Industry Code: 3489 |
13. Time of Completion and Production |
2016-10 |
14. Watershed |
Watershed Name: Bohai Sea Watershed Code: 1 |
15. Sea Area |
Sea Area Name: Sea Area Code: |
- Monitoring Plan
Exhaust Gas Monitoring Plan
Emission Equipment |
Equipment Type |
Number |
Monitoring Point |
Monitoring Index |
Emission Limit Value |
Standard Name |
Monitoring Method |
Monitoring Frequency |
Monitoring Method |
Main Instrument |
Induction Electric Furnace |
Combustion |
MF0004 |
1# Exhaust Pipe (DA001) |
Particulate Matter |
Upper Limit:10mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Online |
1 time/1 hour |
Determination of Particulate Matter and Sampling Method for Gaseous Pollutants in Fixed Pollution Sources GB/T 16157-1996 |
Tongling Blue Light |
2# Natural Gas Heating Furnace |
Combustion |
MF0008 |
2# Exhaust Pipe (DA002) |
Nitrogen Oxides |
Upper Limit:100mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Non-Dispersive Infrared Absorption MethodHJ 692-2014 |
|
2# Natural Gas Heating Furnace |
Combustion |
MF0008 |
2# Exhaust Pipe (DA002) |
Particulate Matter |
Upper Limit:10mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Exhaust Gas from Fixed Pollution Sources Determination of Low Concentration Particulate Matter Gravimetric Method (HJ 836-2017) |
|
2# Natural Gas Heating Furnace |
Combustion |
MF0008 |
2# Exhaust Pipe (DA002) |
Ringelmann Blackness |
Upper Limit:1.0mg/Nm3 |
Emission Standards for Air Pollutants from Industrial Furnaces in Shandong ProvinceDB/37 2375-2019 |
Manual |
1 time/1 half year |
Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007 |
|
2# Natural Gas Heating Furnace |
Combustion |
MF0008 |
2# Exhaust Pipe (DA002) |
Sulfur Dioxide |
Upper Limit:50mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Determination of sulfur dioxide in exhaust from fixed pollution sources Constant potential electrolysis methodHJ 57-2017 |
|
5# natural gas heating furnace |
Combustion |
MF0011 |
3# exhaust pipe (DA003) |
Sulfur Dioxide |
Upper Limit:50mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Determination of sulfur dioxide in exhaust from fixed pollution sources Constant potential electrolysis methodHJ 57-2017 |
|
5# natural gas heating furnace |
Combustion |
MF0011 |
3# exhaust pipe (DA003) |
Particulate Matter |
Upper Limit:10mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Exhaust Gas from Fixed Pollution Sources Determination of Low Concentration Particulate Matter Gravimetric Method (HJ 836-2017) |
|
5# natural gas heating furnace |
Combustion |
MF0011 |
3# exhaust pipe (DA003) |
Nitrogen Oxides |
Upper Limit:100mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Non-Dispersive Infrared Absorption MethodHJ 692-2014 |
|
5# natural gas heating furnace |
Combustion |
MF0011 |
3# exhaust pipe (DA003) |
Ringelmann Blackness |
Upper Limit:1.0mg/Nm3 |
Emission Standards for Air Pollutants from Industrial Furnaces in Shandong ProvinceDB/37 2375-2019 |
Manual |
1 time/1 half year |
Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007 |
|
7# natural gas heating furnace |
Combustion |
MF0018 |
5# exhaust pipe (DA005) |
Ringelmann Blackness |
Upper Limit:1.0mg/Nm3 |
Emission Standards for Air Pollutants from Industrial Furnaces in Shandong ProvinceDB/37 2375-2019 |
Manual |
1 time/1 half year |
Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007 |
|
7# natural gas heating furnace |
Combustion |
MF0018 |
5# exhaust pipe (DA005) |
Nitrogen Oxides |
Upper Limit:100mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Constant potential electrolysis methodHJ 693-2014, Determination of nitrogen oxides in exhaust from fixed pollution sources, Non-dispersive infrared absorption method HJ 692-2014 |
|
7# natural gas heating furnace |
Combustion |
MF0018 |
5# exhaust pipe (DA005) |
Particulate Matter |
Upper Limit:10mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Determination of Particulate Matter and Sampling Method for Gaseous Pollutants in Fixed Pollution Sources GB/T 16157-1996 |
|
7# natural gas heating furnace |
Combustion |
MF0018 |
5# exhaust pipe (DA005) |
Sulfur Dioxide |
Upper Limit:50mg/Nm3 |
Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019 |
Manual |
1 time/1 quarter |
Exhaust Gas from Fixed Pollution Sources Determination of sulfur dioxide Non-Dispersive Infrared Absorption MethodHJ 629-2011, Determination of sulfur dioxide in exhaust from fixed pollution sources, Constant potential electrolysis method HJ/T 57-2000 |
|
Gas boiler |
Combustion |
MF0020 |
Boiler exhaust pipe(DA004) |
Particulate Matter |
Upper Limit:10mg/Nm3 |
Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018 |
Manual |
Once a year |
Exhaust Gas from Fixed Pollution Sources Determination of Low Concentration Particulate Matter Gravimetric Method (HJ 836-2017) |
|
Gas boiler |
Combustion |
MF0020 |
Boiler exhaust pipe(DA004) |
Sulfur Dioxide |
Upper Limit:50mg/Nm3 |
Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018 |
Manual |
Once a year |
Exhaust Gas from Fixed Pollution Sources Determination of sulfur dioxide Non-Dispersive Infrared Absorption MethodHJ 629-2011, Determination of sulfur dioxide in exhaust from fixed pollution sources, Constant potential electrolysis method HJ 57-2017 |
|
Gas boiler |
Combustion |
MF0020 |
Boiler exhaust pipe(DA004) |
Ringelmann Blackness |
Upper Limit:1.0mg/Nm3 |
Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018 |
Manual |
Once a year |
Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007 |
|
Gas boiler |
Combustion |
MF0020 |
Boiler exhaust pipe(DA004) |
Nitrogen Oxides |
Upper Limit:100mg/Nm3 |
Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018 |
Manual |
Once a month |
Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Constant potential electrolysis methodHJ 693-2014, Determination of nitrogen oxides in exhaust from fixed pollution sources, Non-dispersive infrared absorption method HJ 692-2014 |
|
Wastewater monitoring plan
Monitoring point location |
Monitoring Index |
Emission Limit Value |
Standard Name |
Monitoring Method |
Monitoring Frequency |
Monitoring Method |
Latest information