banner

Shandong Bangju Industrial Co., Ltd. Self-Monitoring Plan


Release time:

2024-05-28

Shandong Bangju Industrial Co., Ltd. Self-Monitoring Plan

  • Basic Information of the Enterprise

1.Legal Representative

Wang Lei

2. Former Name

 

3. Organization Code

91371203MA3CB5LU6L-

4. Social Credit Code

91371203MA3CB5LU6L

5. Plan Review Address

Shandong ProvinceProvince (Autonomous Region, Municipality)Jinan CityRegion (City, State, League)

Steel City DistrictCounty (District, City, Banner)

6. Detailed Address of the Enterprise

Shandong ProvinceProvince (Autonomous Region, Municipality) Region (City, State, League)

Steel City DistrictCounty (District, City, Banner) Township (Town)

South New Town, Yihe Road South End, Steel City District, Jinan City, Shandong ProvinceStreet (Village), House Number

7. Geographic Location of the Enterprise

Central Longitude/Central Latitude   117,48,36.25/36,1,20.21

8. Contact Information

Telephone Number:13326226121     Contact:Zhang Yuhui  Mobile Number:

Fax Number:     Postal Code:271104

9. Registration Type

 

10. Enterprise Scale

Medium Type II

11. Enterprise Category

Industrial Enterprise

12. Industry Category

Industry Name:Manufacturing of Other General Parts   Industry Code:  3489  

13. Time of Completion and Production

2016-10

14. Watershed

Watershed Name:     Bohai Sea          Watershed Code:    1               

15. Sea Area

Sea Area Name:               Sea Area Code:                   

 

 

 

  • Monitoring Plan

Exhaust Gas Monitoring Plan

Emission Equipment

Equipment Type

Number

Monitoring Point

Monitoring Index

Emission Limit Value

Standard Name

Monitoring Method

Monitoring Frequency

Monitoring Method

Main Instrument

Induction Electric Furnace

Combustion

MF0004

1# Exhaust Pipe (DA001)

Particulate Matter

Upper Limit:10mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Online

1 time/1 hour

Determination of Particulate Matter and Sampling Method for Gaseous Pollutants in Fixed Pollution Sources GB/T 16157-1996

Tongling Blue Light

2# Natural Gas Heating Furnace

Combustion

MF0008

2# Exhaust Pipe (DA002)

Nitrogen Oxides

Upper Limit:100mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Non-Dispersive Infrared Absorption MethodHJ 692-2014

 

2# Natural Gas Heating Furnace

Combustion

MF0008

2# Exhaust Pipe (DA002)

Particulate Matter

Upper Limit:10mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Exhaust Gas from Fixed Pollution Sources Determination of Low Concentration Particulate Matter Gravimetric Method (HJ 836-2017)

 

2# Natural Gas Heating Furnace

Combustion

MF0008

2# Exhaust Pipe (DA002)

Ringelmann Blackness

Upper Limit:1.0mg/Nm3

Emission Standards for Air Pollutants from Industrial Furnaces in Shandong ProvinceDB/37  2375-2019

Manual

1 time/1 half year

Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007

 

2# Natural Gas Heating Furnace

Combustion

MF0008

2# Exhaust Pipe (DA002)

Sulfur Dioxide

Upper Limit:50mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Determination of sulfur dioxide in exhaust from fixed pollution sources Constant potential electrolysis methodHJ 57-2017

 

5# natural gas heating furnace

Combustion

MF0011

3# exhaust pipe (DA003)

Sulfur Dioxide

Upper Limit:50mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Determination of sulfur dioxide in exhaust from fixed pollution sources Constant potential electrolysis methodHJ 57-2017

 

5# natural gas heating furnace

Combustion

MF0011

3# exhaust pipe (DA003)

Particulate Matter

Upper Limit:10mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Exhaust Gas from Fixed Pollution Sources Determination of Low Concentration Particulate Matter Gravimetric Method (HJ 836-2017)

 

5# natural gas heating furnace

Combustion

MF0011

3# exhaust pipe (DA003)

Nitrogen Oxides

Upper Limit:100mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Non-Dispersive Infrared Absorption MethodHJ 692-2014

 

5# natural gas heating furnace

Combustion

MF0011

3# exhaust pipe (DA003)

Ringelmann Blackness

Upper Limit:1.0mg/Nm3

Emission Standards for Air Pollutants from Industrial Furnaces in Shandong ProvinceDB/37  2375-2019

Manual

1 time/1 half year

Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007

 

7# natural gas heating furnace

Combustion

MF0018

5# exhaust pipe (DA005)

Ringelmann Blackness

Upper Limit:1.0mg/Nm3

Emission Standards for Air Pollutants from Industrial Furnaces in Shandong ProvinceDB/37  2375-2019

Manual

1 time/1 half year

Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007

 

7# natural gas heating furnace

Combustion

MF0018

5# exhaust pipe (DA005)

Nitrogen Oxides

Upper Limit:100mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Constant potential electrolysis methodHJ 693-2014, Determination of nitrogen oxides in exhaust from fixed pollution sources, Non-dispersive infrared absorption method HJ 692-2014

 

7# natural gas heating furnace

Combustion

MF0018

5# exhaust pipe (DA005)

Particulate Matter

Upper Limit:10mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Determination of Particulate Matter and Sampling Method for Gaseous Pollutants in Fixed Pollution Sources GB/T 16157-1996

 

7# natural gas heating furnace

Combustion

MF0018

5# exhaust pipe (DA005)

Sulfur Dioxide

Upper Limit:50mg/Nm3

Comprehensive Emission Standards for Regional Air PollutantsDB37/2376-2019

Manual

1 time/1 quarter

Exhaust Gas from Fixed Pollution Sources Determination of sulfur dioxide Non-Dispersive Infrared Absorption MethodHJ 629-2011, Determination of sulfur dioxide in exhaust from fixed pollution sources, Constant potential electrolysis method HJ/T 57-2000

 

Gas boiler

Combustion

MF0020

Boiler exhaust pipe(DA004)

Particulate Matter

Upper Limit:10mg/Nm3

Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018

Manual

Once a year

Exhaust Gas from Fixed Pollution Sources Determination of Low Concentration Particulate Matter Gravimetric Method (HJ 836-2017)

 

Gas boiler

Combustion

MF0020

Boiler exhaust pipe(DA004)

Sulfur Dioxide

Upper Limit:50mg/Nm3

Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018

Manual

Once a year

Exhaust Gas from Fixed Pollution Sources Determination of sulfur dioxide Non-Dispersive Infrared Absorption MethodHJ 629-2011, Determination of sulfur dioxide in exhaust from fixed pollution sources, Constant potential electrolysis method HJ 57-2017

 

Gas boiler

Combustion

MF0020

Boiler exhaust pipe(DA004)

Ringelmann Blackness

Upper Limit:1.0mg/Nm3

Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018

Manual

Once a year

Determination of Smoke Blackness from Fixed Pollution Source Emissions Ringelmann Smoke Blackness Chart MethodHJ/T 398-2007

 

Gas boiler

Combustion

MF0020

Boiler exhaust pipe(DA004)

Nitrogen Oxides

Upper Limit:100mg/Nm3

Shandong Province Boiler Atmospheric Pollutant Emission StandardsDB37/2374-2018

Manual

Once a month

Exhaust Gas from Fixed Pollution Sources Determination of Nitrogen Oxides Constant potential electrolysis methodHJ 693-2014, Determination of nitrogen oxides in exhaust from fixed pollution sources, Non-dispersive infrared absorption method HJ 692-2014

 

 

 

 

Wastewater monitoring plan

Monitoring point location

Monitoring Index

Emission Limit Value

Standard Name

Monitoring Method

Monitoring Frequency

Monitoring Method